Latest NS0-173 Exam NS0-173 Dumps 100% Free Download
We ensures to provide the most update NS0-173 real exam questions with the most accurate answers. We Netapp Other Certification {keywords} are the most complete and authoritative NS0-173 dumps with which one can pass the Netapp Other Certification Latest NS0-173 exam questions exam in an easy way. Preparing for Netapp Other Certification Apr 13,2022 Latest NS0-173 pdf dumps Cisco and NetApp FlexPod Design Specialist exam is really a tough task to accomplish. But We will simplified the process.
We Geekcert has our own expert team. They selected and published the latest NS0-173 preparation materials from Official Exam-Center.
The following are the NS0-173 free dumps. Go through and check the validity and accuracy of our NS0-173 dumps.These questions are from NS0-173 free dumps. All questions in NS0-173 dumps are from the latest NS0-173 real exams.
Question 1:
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)
A. a two-node AFF A200 with a 3.8 TB NSE SSD
B. a DS224C with twenty-four 3.8 TB SSDs
C. a DS4246 with twenty-four 6 TB NL-SAS HDDs
D. a two-node FAS8200 with a 4 TB NL-SAS HDD
Correct Answer: BD
Question 2:
A customer wants to deploy a FlexPod solution that involves directly connecting the NetApp AFF storage using the FCoE protocol to the Cisco UCS Fabric Interconnects.
In this scenario, which Cisco UCS Fibre Channel mode would be used to accomplish this task?
A. trunk mode
B. end host mode
C. switching mode
D. access mode
Correct Answer: C
Reference: https://www.netapp.com/media/16411-nva-0025-deploy.pdf
Question 3:
The storage administrator must change the vHBA settings bound to a template associated with a production server.
What happens when the settings are reconfigured in this scenario?
A. The vHBA configuration change does not affect LUN access.
B. The server that is associated with the service profile reboots.
C. The service profile template that is associated with the server is initialized.
D. The vHBA template is deleted from UCS Manager.
Correct Answer: C
Question 4:
A customer has installed FlexPod and verified that all wiring connections are correct. However, the customer cannot see any FC LUNs from the NetApp AFF systems.
In this scenario, which three configuration elements should the customer verify? (Choose three.)
A. FC zoning
B. igroup configuration
C. ALUA settings
D. FC portsets E. MTU configuration
Correct Answer: BDE
Question 5:
Your customer has a FlexPod solution with a 2-node switchless ONTAP system, Cisco Nexus 93108 switches, and Cisco UCS B-Series servers. The customer wants to expand to a 4-node ONTAP storage cluster.
Which configuration is valid for expansion?
A. Use the existing Nexus 93108 switches for the cluster interconnect.
B. Add two Nexus 3232C switches for the cluster interconnect.
C. Add two Nexus 93108 switches for the cluster interconnect.
D. Add one Nexus 3232C switch for the cluster interconnect.
Correct Answer: B
Question 6:
A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.
Which tool satisfies the requirements of this customer\’s heterogeneous environment?
A. UCS Central
B. NetApp OnCommand Unified Manager
C. NetApp OnCommand Insight
D. UCS Director
Correct Answer: D
Question 7:
An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.
In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?
A. monitor port
B. appliance port
C. uplink port
D. server port
Correct Answer: C
Question 8:
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)
A. Cisco
B. VMware
C. Microsoft
D. NetApp
E. Red Hat
Correct Answer: ADE
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/ flexpod_openstack_osp6_design.html
Question 9:
Click the Exhibit button.
A customer wants to ensure that FlexPod Datacenter connections to the storage layer are highly available. Which two configurations shown in the exhibit satisfy the customer\’s requirements? (Choose two.)
A. I.
B. II.
C. III.
D. IV
Correct Answer: CD
Question 10:
A customer has a FlexPod Express configuration with a FAS2720 system. The company has opened a new remote location and will purchase a FlexPod Express configuration with a FAS2750 system. The business requires that the data be replicated to the new location.
Which two software applications accomplish this task? (Choose two.)
A. SnapVault
B. SnapRestore
C. SnapMirror
D. FlexCache
Correct Answer: CD
FlexClone: Instant virtual copies with file and volume granularity SnapMirror: Integrated data replication technology for simple, efficient, flexible disaster recovery and backup use cases
Reference: https://www.inneo.ch/files/content/Informationstechnologien/Storage-Server-Netzwerk/ datenblatt-netapp-fas-2700-storage.pdf
Question 11:
A customer wants to design a FlexPod configuration based on a CVD that was published 10 months ago. The customer wants to ensure that they are using the latest hardware and software versions.
In this scenario, which two tools are used to identify the latest supported hardware and software? (Choose two.)
A. NetApp Interoperability Matrix Tool
B. NetApp OnCommand System Manager
C. Cisco UCS Hardware and Software Interoperability Matrix
D. Cisco UCS Director
Correct Answer: CD
C: When using this matrix to determine recommended driver versions for you server configuration, please reference the server\’s Blade/Rack Bundle firmware version for the recommended driver in the event that your servers are running Mixed Firmware from your Infrastructure Bundle.
D: Cisco UCS Director delivers unified, highly secure management for supported compute, network, storage, and virtualization platforms and for the industry\’s leading converged infrastructure solutions
Reference: https://ucshcltool.cloudapps.cisco.com/public/# https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-director/release-notes/6-7/cisco-ucsdirector-release-notes-67.html
Question 12:
You are designing a FlexPod solution that requires 32 ports running at 40 Gbps.
To satisfy this requirement, which Cisco Fabric Interconnect should you deploy?
A. 6332-16UP
B. 6332
C. 6248UP
D. 6296UP
Correct Answer: B
FI 6332 is a one-rack-unit (1RU) 40 Gigabit Ethernet, and FCoE switch offering up to 2.56 Tbps throughput
and up to 32 ports. The switch has 32 40Gbps fixed Ethernet.
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/
flexpod_esxi60u2_fc_design.html
Question 13:
You are configuring high availability within the network layer of your FlexPod configuration.
In this scenario, what are two Cisco best practices for designing vPC on your Cisco 9000 Series switches? (Choose two.)
A. Peer keep-alive connectivity between the switches should be established.
B. A minimum of four 10GB Ethernet connections are required for vPC.
C. The vPC auto-recovery feature should be enabled.
D. Port channels should be configured for LACP passive mode.
Correct Answer: AB
vPC also relies on the periodic keepalive messages to determine when one of the connected devices on the peer link fails. vPC peer link ?The link used to synchronize states between the vPC peer devices. Both ends must be on 10-Gigabit Ethernet or 40-Gigabit Ethernet interfaces. Reference: https://www.cisco.com/ c/en/us/td/docs/switches/datacenter/nexus9000/sw/6-x/interfaces/configuration/guide/ b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide/ b_Cisco_Nexus_9000_Series_NX- OS_Interfaces_Configuration_Guide_chapter_0111.html
Question 14:
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)
A. Cluster mode
B. Direct Connect mode
C. SingleConnect mode
D. DualWire Management mode
E. Multipath mode
Correct Answer: BCD
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management. SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect. Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack-Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C-Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-SeriesIntegration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html
Question 15:
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?
A. 2204XP.
B. 2208XP
C. 2232
D. 2304
Correct Answer: A
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP ports that connect the blade chassis to the fabric interconnect. Reference: https://www.cisco.com/c/dam/ en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/spec_sheet_c17644224.pdf