NS0-192 practice exam

[PDF and VCE] Free Geekcert NetApp NS0-192 PDF Real Exam Questions and Answers Free Download

How to pass Netapp Other Certification Latest NS0-192 practice exam? Geekcert gives all candidates the 100% guaranteed Netapp Other Certification Newest NS0-192 free download NetApp Certified Support Engineer exam dumps. We help you to face your Netapp Other Certification Newest NS0-192 QAs exam with confidence. Successful candidates share their reviews about our Netapp Other Certification Hotest NS0-192 vce dumps NetApp Certified Support Engineer dumps. Now Geekcert supplies the most effective Netapp Other Certification Jan 14,2022 Latest NS0-192 QAs VCE and PDF dumps. We ensure our Netapp Other Certification Newest NS0-192 study guide exam questions are the most complete and authoritative compared with others, which will ensure your Netapp Other Certification Latest NS0-192 QAs exam pass.

Geekcert braindumps Geekcert dumps free download. Geekcert – the most professional provider of all NS0-192 certifications. pass all the NS0-192 exam easily. Geekcert provides you the easiest way to pass your NS0-192 certification exam. you are only successful with NS0-192 testing engine in your it certification – Geekcert!

We Geekcert has our own expert team. They selected and published the latest NS0-192 preparation materials from NetApp Official Exam-Center: https://www.geekcert.com/ns0-192.html

The following are the NS0-192 free dumps. Go through and check the validity and accuracy of our NS0-192 dumps.Although questions are from NS0-192 free dumps, the validity and accuracy of the NS0-192 dumps are absolutely guaranteed.

Question 1:

A customer recently performed an ONTAP upgrade and would like to confirm the successful completion of the process. Which three actions would satisfy this requirement? (Choose three.)

A. Execute the version command at the cluster shell.

B. Verify the version from the new AutoSupport that was automatically triggered after an upgrade.

C. A System Message notification will be shown upon reboot after a successful upgrade.

D. Execute the system node upgrade-revert show command at the cluster shell.

E. Execute the system node upgrade-revert show-task-status command at the cluster shell.

Correct Answer: ACD

Reference: https://library.netapp.com/ecm/ecm_download_file/ECMLP2492712


Question 2:

A manager wants a volume to have a guaranteed 300 MB/s of read performance. You explain that you cannot do this on FAS storage running ONTAP 9.3 backed by 10,000 RPM disks. What is the reason for this response?

A. Throughput floors apply to only iSCSI access.

B. Throughput floors can only guarantee up to 125 MB/s.

C. Throughput floors require a license.

D. Throughput floors require AFF.

Correct Answer: D


Question 3:

Click the exhibit button.

Based on the QoS output from the storage controller, your database administrator is complaining of slow read and write performance. Referring to the exhibit, what would be two appropriate actions to improve performance for both reads and writes? (Choose two.)

A. Move the workload to an SSD aggregate.

B. Apply a QoS maximum policy to the csdata-wid1234 workload.

C. Add a Flash Pool to the existing aggregate.

D. Upgrade the controller\’s NVRAM.

Correct Answer: BC


Question 4:

You are migrating volumes from an older aggregate to a new aggregate using the vol move command. You notice that, after completion, access to these volumes is slower until a certain process finishes. Which process is causing the problem in this scenario?

A. deswizzling

B. active bitmap rearrangement

C. snap create

D. container block reclamation

Correct Answer: D


Question 5:

Click the Exhibit button.

Your customer\’s disks are showing 100% utilization, but the customer sees minimal user I/O. You collect statistics using the statit command over a 10-second time period as shown in the exhibit. In this scenario, what is the problem?

A. The end users are doing a lot of reads on the SATA disks that are using vStorage APIs

B. Disk 0a.16 is being used to reconstruct data from a failed disk in the aggregate.

C. Disk 0a.16 is faulty and should be replaced.

D. The network has too many multicast packets.

Correct Answer: D


Question 6:

When you expand an aggregate, the spare partitions can be added as only a new RAID group, even though the current RAID group size is large enough for the current and new partitions. In this scenario, which statement is correct?

A. The partitions to be added share disks with the partitions in the existing RAID group.

B. RAID group size is used only when dealing with non-partitioned disks.

C. Only nonpartitioned disks can be added to a RAID group with existing partitions.

D. The aggregate must be converted to RAID-TEC to expand RAID groups using partitions.

Correct Answer: A


Question 7:

A customer explains that the Active IQ section of the NetApp Support site indicates that their controller has not called home within the past three months. They are not using a mail host to deliver AutoSupport notifications. When troubleshooting the AutoSupport message, you enter the event log show -messagename asup.post* command.

In this scenario, what would you expect to see on the console?

A. event-management system (EMS) events for the AutoSupport system that are related to SMTP

B. a history of all error events related to the AutoSupport system

C. event-management system (EMS) events for the AutoSupport system that are related to HTTP/HTTPS

D. event-management (EMS) events for the AutoSupport system that are related to any protocol

Correct Answer: A


Question 8:

An administrator just upgraded the controllers and wants to nondisruptively implement Advanced Drive Partitioning (ADP) as part of the change. Which statement is correct in this scenario?

A. ADP cannot be implemented on this system.

B. ADP can be implemented as long as all of the on-board drives do not contain data.

C. ONTAP does not support ADP.

D. ADP can be implemented, but only with a complete data-wipe and initialization.

Correct Answer: D


Question 9:

A customer has an SVM with an SSD aggregate that is reaching capacity. They want to move the data to another SVM with attached SATA drives. Which two ONTAP features will accomplish this task? (Choose two.)

A. volume copy

B. volume move

C. volume rehost

D. volume relocate

Correct Answer: BC

Reference: https://whyistheinternetbroken.wordpress.com/2016/06/08/volume-rehosting-ontap9/


Question 10:

Users are unable to access data stored on an ONTAP cluster. The storage aggregate show command reports that the aggregates are offline and wafl_inconsistent. Which action would you perform to recover the aggregate?

A. Perform an aggregate copy and delete the source aggregate.

B. Execute the storage aggregate online command from the cluster shell.

C. Use file system recovery tools to recover the aggregate.

D. Execute the aggr online command from maintenance mode.

Correct Answer: C


Question 11:

A customer has a company-wide power outage scheduled and needs to gracefully power off a 2-node cluster. In this scenario, which of two steps should be performed? (Choose two.)

A. Use the halt -node * -skip-lif-migration-before-shutdown true -inhibit-takeover true command.

B. Invoke an AutoSupport message to indicate a planned maintenance time.

C. Use OnCommand System Manager to halt the controllers.

D. Use the halt -node * command.

Correct Answer: AD

Reference: https://library.netapp.com/ecm/ecm_download_file/ECMLP2492713


Question 12:

A customer created a new volume on an SVM for testing. During the first day of testing, the customer copied data to the volume using NFS and consumed 75% of the free space. The second day of testing required the existing data to be deleted and replaced by an equal amount of different data. During the copy, an error message stated that the volume was full.

What would explain the observed error?

A. The user did not have permissions to the export.

B. The client lost connectivity to the export.

C. Vscan stopped the write due to an infection.

D. The old data is still contained within a snapshot.

Correct Answer: B


Question 13:

A customer recently experienced a panic on one node of an ONTAP cluster. Prior to performing the giveback, they want to know what caused the panic. You request data from the customer to assist Support in determining the cause of the panic.

What information should be requested in this situation? (Choose three.)

A. panic string

B. Perfstat

C. core dump

D. message logs

E. packet trace

Correct Answer: ACD


Question 14:

After you replace a network adapter card in a NetApp node, what should be done before you put the node back into production?

A. From the cluster::> prompt, use the sldiag utility for testing before rejoining the cluster.

B. From the LOADER> prompt, use the boot_diags command and use the sldiag utility for testing.

C. From the LOADER> prompt, use the boot_ontap command to boot into ONTAP and use the sldiag utility for testing.

D. From the cluster::> prompt, use the set diag command for testing before rejoining the cluster.

Correct Answer: C


Question 15:

A customer performed maintenance last weekend and power cycled both FAS8060 nodes of a 2-node ONTAP 9.2 cluster. The customer is concerned about port errors seen from the system ha interconnect port show command output.

Which two steps would you perform in troubleshooting this condition? (Choose two.)

A. Use the system ha interconnect link off/on command to manually reset the HA interconnect Link 0 and Link 1 on both nodes.

B. Perform a takeover/giveback of both nodes.

C. reset the counters using the system ha interconnect statistics clear-port command.

D. Use the system ha interconnect flush command to manually reset the HA interconnect Link 0 and Link 1 on both nodes.

Correct Answer: AB